Electric heat tracing products BSX Freeze Protection and Temperature Maintenance up to 65°CMaximum Exposure Temperature 85°CAvailable Watt Densities at 10°C 9, 15, 25, 32 W/mSupply Voltage 230 V RSX Freeze Protection and Temperature Maintenance up to 65°CMaximum Exposure Temperature 85°CAvailable Watt Densities at 10°C 48 W/mSupply Voltage 230 V KSX Freeze Protection and Temperature Maintenance up to 121°CMaximum Exposure Temperature 121°CAvailable Watt Densities at 10°C 15, 31, 48, 64 W/mSupply Voltage 230 V HTSX Freeze Protection and Temperature Maintenance up to 121°CMaximum Exposure Temperature 250°CWithstands Temperatures Associated with Steam PurgingAvailable Watt Densities at 10°C 9, 18, 27, 37, 48, 64 W/mSupply Voltage 230 V VSX Freeze Protection and Temperature Maintenance up to 149°CMaximum Exposure Temperature 250°CWithstands Temperatures Associated with Steam PurgingAvailable Watt Densities at 10°C 15, 32, 48, 64 W/mSupply Voltage 230 V Heat Tracing Systems Accessories Power, Splice and Termination KitsMechanical ThermostatsElectronic Control and Monitoring ModulesPower Distribution and Control PanelsSystem Communications Software Power-Limiting Heating Cables HPT PTC Coiled Resistor Alloy Heating ElementCut-to-Length Prallel CircuitryNicke-Plated Copper Bus WiresMetallic Braids for Grounding PurposesFluoropolymer OverjacketWorldwide Approvals Freeze Protection and Temperature Maintenance up to 149°CMaximum Exposure Temperature 260°CAvailable Watt Densities at 10°C 14, 28, 42, 57 W/mSupply Voltage 230 V Constant Watt Heating Cables FP Nichrome Heating ElementCut-to-Length Prallel Circuitry3.3 mm Copper Bus WiresMetallic Braids for Grounding PurposesFluoropolymer OverjacketWorldwide Approvals Freeze Protection and Temperature Maintenance up to 65°CFoundation Heating Maximum Exposure Temperature 200°CMaximum Watt Densities at 10°C 25 W/mSupply Voltage 230 V and 400V Mineral Insulated Heating Cables MI High Temperature Magnesium Oxide DielectricHigh Power Output CapabilitiesAvailable in Three Outer-Sheath Materials Freeze Protection and Temperature Maintenance up to 500°CMaximum Exposure Temperature 600°CAvailable Watt Densities up to 260 W/mSupply Voltage up to 600 V Series Resistance Heating Cables TESH Long Circuit Lengths with Fewer Power PointsStabilised Designs Possible Using Thermon SoftwareMetallic Braids for Earthing Purposes Long Line Freeze Protection and Temperature MaintenanceMaximum Exposure Temperature 260°CAvailable Watt Densities up to 25 W/mSupply Voltage up to 750 V Skin Effect Heating Systems ThermTrac Rugged Heat Tube to Generate HeatCircuit Lengths up to 25 kmEach System Fully Factory – Engineered Power Outputs up to 165 W/mOperating Voltages up to 5 kVMaintenance Temperatures up to 200°CExposure Temperatures up to 260°C You will find more detailed information in our brochure. Download EN PDF